Armoured OS2 Duplex Patch and Adapter Cables

Robust fibre-optic patch cables for protected fibre connections in offices, data centres and FTTx applications.
The EasyLan® armoured patch cable has been developed for demanding indoor fibre-optic connections. Its armoured cable construction provides enhanced mechanical protection for the optical fibre, making it particularly suitable for installations in which patch cables are exposed to increased mechanical stress.
The cable is available in simplex and FIG8 duplex versions. Connector configurations include LC/APC, SC/APC and LC/APC to SC/APC adapter cables. The white outer sheath and compact cable diameter of 2.7 mm enable neat and space-saving installation.
The EasyLan® armoured patch cable is suitable for robust indoor fibre-optic connections, particularly in network cabinets and technical rooms, FTTx and FTTH installations, data-centre and building cabling, installation areas exposed to increased mechanical stress, and environments in which additional protection against pressure, foot traffic or damage is required. The specified bending radius must also be observed for armoured fibre-optic patch cables. The armouring improves mechanical protection but does not replace professional cable installation.
Custom lengths are available on request.
Benefits:
- Armoured construction for enhanced mechanical protection
- Compact cable diameter of 2.7 mm
- Available in simplex and FIG8 duplex versions
- Connector configurations: LC/APC, SC/APC and LC/APC to SC/APC
- Singlemode OS2 for FTTx and building-network applications
- White cable sheath for discreet and neat installation
- Suitable for technical rooms, distribution cabinets and demanding indoor installations
Features:
- Application: Fibre-optic connection and adapter cable
- Area of application: Indoor, office, data centre and FTTx
- Fibre type: Singlemode 9/125 µm
- Category: OS2 / G.657.A2
- Polish type: APC 8°
- Connectors: LC/APC, SC/APC
- Sheath: LSZH, white
- Ferrule: Ceramic
- Armouring: Stainless-steel spiral tube
Technical Data:
- Minimum static bending radius: 10 × OD
- Minimum dynamic bending radius: 20 × OD
- Tensile load: 120 N long-term / 225 N short-term
- Operating temperature: −25 °C to +70 °C
- Storage temperature: −25 °C to +70 °C
| Description | Order Code xxxx = length in dm |
| EasyLan® Armoured OS2 FIG8 Duplex Patch Cable, LC/APC–LC/APC, 2.7 mm, White | ADLLxxxx |
| EasyLan® Armoured OS2 FIG8 Duplex Patch Cable, SC/APC–SC/APC, 2.7 mm, White | ADSSxxxx |
| EasyLan® Armoured OS2 FIG8 Duplex Patch Cable, LC/APC–SC/APC, 2.7 mm, White | ADLSxxxx |